Features
- Dual frequency - Multi-Code or Stanley compatible; jumper selectable.
- 12-24 Volts AC or DC.
- Auto voltage sensing - no jumpers to set.
- Single relay and two relay models.
- Supplied with whip antenna, three feet of coaxial cable and bulkhead connector.
The 1099-50 is a two auto sensing Multi-Code or Stanley compatible format gate receiver. They eliminate any chance of damage to either the gate operator or themselves from running off the wrong voltage. Nearly all gate operators offer either 24 or 12 volts AC or DC as accessory power. Because the receiver is auto sensing, it recognizes the gate operator's correct voltage. As a result, installers can be assured of always having the correct model gate receiver on the truck.
The receiver can operate from 12-30 volts AC or 10.5-30 volts DC and are normally powered from the gate operator. The relay contact(s) are rated at 30 VAC/DC up to 5 Amps.
The receiver supports transmitters that use the Multi-Code format (300 MHz ), as well as the Stanley compatible (310 MHz ) format. The format supports 1,024 system codes for the 1099-50. The 1099-50 has a single relay and replaces three different Multi-Code gate receivers. It is designed for use with automatic gate operators or systems where a remote antenna is needed. The 1099-50 comes with a 9-inch local antenna, three feet of 75 ohm coaxial cable, and a bulkhead connector for locating the antenna outside the gate operator enclosure. The receiver also includes audio test points for connecting audio listening equipment for troubleshooting.
Specifications
RF
300 (Multi-Code) and 310 (Stanley compatible) MHz +/- 250 KHz;format support 1,024 system codes
OUTPUTS
Relay(s): 1099-50 = 1CH; each relay is a Form C relay (NC connection available on PCB) rated at 30V AC/DC up to 5 Amps RF Test Points: two test points for connecting of an audio listening device to hear what the receiver is hearing
INPUTS
Antenna: 75 Ohm F connector Dip Switch: used to set the system code; on the 1099-50, all 10 switches can be used for the system code
POWER
12 - 30 VAC or 10.5 - 30 VDC; 16 mA nominal, 50 mA maximum while relay is triggered
OPERATING TEMPERATURE
-4F to +140F (-20C to +60C)
DIMENSIONS
3.625 in W x 5.25 in H x 1.5 in D (92 x 133 x 38 mm)
Electrical Connections
36" 22AWG wires on removable connectors: Power: red and black wires CH1 Relay: 2 gray wires CH2 Relay: 2 yellow wires
STANDARD EQUIPMENT
1099-50; 9.5" whip antenna, 3 ft coaxial cable, bulkhead connector, mounting hardware
REGULATORY
FCC Part 15