The 28SA Plus is a highly sophisticated, yet simple to use, card access control unit for single or multi-door applications. Simply place the card on the stainless steel TOUCH CARD® Reader plate, and the card is read instantly and accurately. Patented slotless TOUCH CARD® Reader technology protects the unit from weather and vandalism.
The unit may be programmed with a PC either locally or with the use of a modem. Basic programming functions can also be accomplished by using programming cards. Transaction information is stored by the unit and may be downloaded to a PC or printer. Up to 128 28SA Plus units can be connected together in a single twisted pair RS-485 network using optional Modules and Software for Windows® 95/ 98/NT/2000.
A remote reader may be connected to the 28SA Plus to allow access control in both directions through a single passageway, including true IN/OUT anti-passback capability. Three inputs are provided which are user programmable as Door Monitor, Tamper Monitor, Remote Inactive, Remote Open, Arming Circuit, Bell, or User Defined. The limited use feature allows cards to be programmed to work for a specified number of uses, days, weeks, or days after the first use.
The SA28 can be configured to work in both a online and offline scenario. This access controller / reader combo can be used in a 2 lane system with true or time anti-passback. The SA28 can also be used in a single lane, stand alone, offline proximity reader system with up to a 3' read range.
Features
- 65,500 Card Capacity
- 5,000 Stored Transactions
- 15 Time Zones / 32 Holidays
- Connect up to 128 Units with Optional Modules and Software
- Audit Trail - Upload to PC or Connect to Serial Printer
- Modem Capability for Remote Locations
- TCP/IP Capability for LAN Connection
- Weather Resistant for Outdoor Installation
- True IN/OUT or Timed Anti-passback
Specifications
POWER REQUIREMENTS: Without Remote Reader; 12 to 24 VAC or DC,125 mA
OUTPUTS:
Latch & Alarm Shunt; DPDT contact, 3A, 125 to 277 VAC or 30 VDC.
Tamper (optional); SPDT contact, 115 AC, 2A maximum.
INPUTS:
Auxiliary 1 (Door Monitor)*Requires SPST contact closure.
Auxiliary 2 (Disabled)*Requires SPST contact closure.
Auxiliary 3 (Disabled)* Requires SPST contact closure *Factory Default - can be changed via PC.
COMMUNICATION:
RS-232 (5-wire Shielded Cable)- Serial RS-232. Up to 38.4K Baud, full duplex, (8N1)
RS-485 (Single Twisted Pair) - Requires Optional Network Module See Separate Data Sheet for Specifications
Remote Reader - 31 bit or 26 bit Wiegand type input, 10-21 VDC @ 150 mA supplied to remote reader,depending on input voltage supplied to 28SA PLUS
Modem - Requires Hayes compatible - 1.2 to 38.4k baud
LAN - Requires external device server
Printer - Serial Printer (or Parallel printer with serial converter)
ENVIRONMENT:
Ambient Temperature -40F to 158F (-40C to 70C)
Humidity - 0% to 95% relative humidity (non condensing)
OPERATIONAL
Memory - Non-volatile
Card Capacity - Up to 65,500
Limited Use Cards- 4,000 programmable from 1-5000 uses, days, weeks
Transaction Storage - 5000 events
Time Zones - 15 for card access, 1 door unlock time zone; full week plus holiday in one- half hour segments; 32 programmable holidays; selectable automatic daylight saving time.
Facility Code - Up to 3 different codes simultaneously (Max. # of cards 65,500)
Latch/Alarm Shunt Timer - Programmable from 1/4 to 30 seconds
Anti-passback - Real or Timed from (1 to 30 minutes); hard or soft
Auxiliary Inputs (3) - Programmable for door monitor, tamper monitor, remote open, remote inactive, bell, arming circuit or user defined